Device Recall Nakanishi Inc. 의 리콜

U.S. Food and Drug Administration에 따르면, 해당 리콜 는 United States 에서 Nakanishi Inc. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    74666
  • 사례 위험등급
    Class 2
  • 사례 연번
    Z-2674-2016
  • 사례 시작날짜
    2016-07-08
  • 사례 상황
    Terminated
  • 사례 국가
  • 사례 종료 날짜
    2018-06-25
  • 사례 출처
    USFDA
  • 사례 출처 URL
  • 비고 / 경고
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • 데이터 추가 비고
    Handpiece, air-powered, dental - Product Code EFB
  • 원인
    Through an error, the labeling failed to include the symbol or other text indicating that the diamond coated tips were single use only. a contributing factor to this error is that in other markets such as japan, the diamond coated tips are multiple use and are not limited to single use only. the tips are stainless steel with a coating of fine diamond powder. the tips are sold non-sterile and are to be sterilized prior to first use. the tips were cleared as single use only. this problem was discovered during an ongoing, proactive, quality system improvement plan that was initiated by nakanishi in october 2014. because the correct instructions for sterilization are not available, it is possible that the devices might not be sterile prior to use. the absence of the single use statement introduces a risk of cross-contamination if the tips are reprocessed and reused.
  • 조치
    Naknishi sent out an URGENT : MEDICAL DEVICE CORRECTION letter on July 18, 2016 describing the potential safety issue regarding their Diamond Coated Products. The firm is requesting customers take the following actions: 1. Examine their inventory immediately to determine if they have any product, both used and unused, bearing any of the Nakanishi Product Codes listed in List of Products enclosed with this letter. 2. Immediately dispose of any USED product according to applicable regulations. 3. Segregate any UNUSED product for return to Nakanishi. 4. In order for the firm to complete their records, they are requesting that customers complete the enclosed Correction Activity Sheet and FAX or Mail to: NSK America, Corp. 1800 Global Parkway, Hoffman Estates, IL 60192 US Facsimile: 1-800-838-9328 Customers with questions were advised to Telephone: 1-888-675-1675. NSKrecall@NSKDental.com For questions regarding this recall call 847-843-7664.

Device

  • 모델명 / 제조번호(시리얼번호)
    Waiting for clarification from the firm.
  • 의료기기 분류등급
  • 의료기기 등급
    1
  • 이식된 장치?
    No
  • 유통
    Nationwide Distribution to Illinois, Florida and Georgia.
  • 제품 설명
    Diamond Coated Tips and Burs are accessories to the air powered dental handpiece (S-MAX pico) || The intended use of the tips is based on the parent device. For burs used with the dental handpieces, the intended use is general dental actions such as removing carious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations and restorations and polishing teeth.
  • Manufacturer

Manufacturer

  • 제조사 주소
    Nakanishi Inc., 700, Shimohinata, Kanuma Japan
  • 제조사 모회사 (2017)
  • Source
    USFDA