magnetic resonance equipment

제조사

  • 제조사 모회사 (2017)
  • 제조사 의견
    “We are in constant communication with regulatory agencies and competent authorities worldwide which allows us to implement global recalls or in-country communication quickly and effectively,” Abbott, which now owns St. Jude Medical told ICIJ in a statement. In addition to sending global notices to physicians worldwide, we also make sure that product advisories are available online and classification of product recalls and product advisories are determined by global regulatory bodies which can impact the timing in any given country. MD companies follow varying regulations in different countries. In come countries software is not regulated so a recall in one country related to software would not be classified as a recall or field action in another. In addition, review cycles within the regulatory process can be different in each country which can impact communication and recall timing.
  • Source
    NIDFSINVIMA

유사한 이름을 가진 의료기기 1건 유사한 이름을 가진 의료기기 13 건

데이터에 대해 더 자세히 알아보기 여기

  • 모델명 / 제조번호(시리얼번호)
    T5, T10-NT, ACSNT, Intera 0.5T / 1.0T / 1.5T, Achieva 1.5T, Multiva 1.5T
  • 제품 설명
    The intended use of PHILIPS MRI medical electromedical systems is class IIa diagnostic equipment. The systems can generate transverse and spectroscopic images in any orientation of the internal structure of the head, body or extremities. Magnetic resonance images represent the spatial distribution of protons or other nuclei with spin. The appearance of the images is determined by different physical properties of tissue and anatomy, and the technique of acquisition by applied MRI. The image acquisition process can be synchronized with the patient's breathing or with the cardiac cycle. The systems can use combinations of images to generate physical parameters and related derived images. The images, the spectra, and the measurements of physical parameters, after being interpreted by the medical specialist, provide information that can facilitate the diagnosis and planning of the therapy. The accuracy of certain physical parameters depends on the system and the acquisition parameters, and must be regulated and validated by the clinical user. For some studies, the use of contrast media may be essential. During an MRI exam, energy is transferred to the patient in the form of radio frequency waves, changing magnetic fields and acoustic noise. The PHILIPS magnetic resonance systems do not emit radiation-ionizing agents. Non-invasive diagnostic equipment
  • Manufacturer
하나 더 8 건 더