ADVIA 560

제조사

유사한 이름을 가진 의료기기 1건 유사한 이름을 가진 의료기기 15 건

데이터에 대해 더 자세히 알아보기 여기

  • 모델명 / 제조번호(시리얼번호)
    ADVIA 560, serial S020202, S020201, S020200 and S020197, with software version 4.1.2133
  • 제품 설명
    The ADVIA 560 and 360 HEMATOLOGY SYSTEM are a fully automated, high-quality hematology system for use in in vitro diagnostics in clinical laboratories. The system uses the impedance method for the measurement of deleucocyte concentrations (WBC), erythrocytes (RBC) and platelets (PLT). The concentration of hemoglobin (HGB) of the red blood cells semide by photometric refraction. The system provides a differential measurement of the WBC 5-part leukocyte formula (LYM%, MON%, NEU%, EOS%, BAS%) by laser-based optical flow cytometry technology. The ADVIA 560 and the ADVIA 360 HEMATOLOGY SYSTEM identify patients with hematological parameters within and outside the established reference ranges. The system can process up to 100 ul of whole blood that is agicoagulated, automatically for hematology.
  • Manufacturer
  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    The ADVIA 560 AND 360 HEMATOLOGY SYSTEM is a fully automated, high quality hematology system for use in in vitro diagnostics in clinical laboratories. The system uses the impedance method for the measurement of leukocyte (WBC), erythrocyte (RBC) and platelet (PLT) concentrations. The hemoglobin concentration (HGB) of red blood cells is measured by photometric refraction. The system provides a differential measurement of the leukocyte formula of 5 parts of WBC (LYM%, MON%, NEU%, EOS%, BAS%) by laser-based optical flow decitometer technology. The ADVIA 560 and the ADVIA360 HEMATOLOGY SYSTEM identify patients with hematological parameters inside and outside the established reference ranges. The system can process up to 100 μl of blood completely anticoagulated, automatically for hematology.
  • Manufacturer
  • 모델명 / 제조번호(시리얼번호)
    All serial numbers of ADVIA 560 Hematology Systems.
  • 의료기기 분류등급
  • 의료기기 등급
    2
  • 이식된 장치?
    No
  • 유통
    Worldwide Distribution - US Distribution including Puerto Rico and to the states of : California, Illinois, Washington and Wisconsin., and to the countries of : Angola, Austria, Canada, Chile, Colombia, Czech Republic, France, Germany, India, Italy, Kenya, Netherlands, Norway, Portugal, Singapore, Slovenia, Spain, Turkey, Uganda and United Kingdom.
  • 제품 설명
    ADVIA 560 Hematology Systems, Siemens Material Number (SMN) 11170842, IVD || The ADVIA 560 Hematology System is a fully-automated, high-quality hematology system for in vitro diagnostic use in clinical laboratories
  • Manufacturer