Triathlon Femoral Distal Fixation Peg; Catalog Number 5575-X-00; Manufactured by Stryker Howmedica Osteonics Corp., Howmedica Osteonics Corp., 325 Corporate Drive, Mahwah, NJ 07430 USA A Subsidiary of Stryker Corp. || One single unit to a package. || Triathlon Distal Femoral Fixation Pegs are made available separate from the Triathlon Posteriorly Stabilized Femoral Component. These distal femoral fixation pegs are an accessory to the Triathlon Femoral Component and are optional for use. These pegs are designed to provide rotational stability and to aid the surgeon in the placement of the femoral component on the prepared distal femur. The Triathlon Distal Femoral Fixation Pegs are fabricated from wrought cobalt alloy. The distal portion of the fixation peg is thread to allow the peg to be assembled to the distal threaded hole in the Triathlon femoral component. The proximal portion of the peg is recessed to allow the use of a wrench to assemble the peg into the femoral complement.
Worldwide Distribution - USA , Sweden, Germany; France, Portugal, UK, Canada, Australia, and New Zealand,
제품 설명
Triathlon PKR Peg Drill, Catalog Number: 5650-4-512 (Size 1-2 Peg Drill); Catalog Number: 5650-4-536 (Size 3-6 Peg Drill); || Howmedica Osteonics Corp. 325 Corporate Drive Mahwah, NJ 07430 || The Triathlon-PKR Knee System is indicated for primary partial knee resurfacing (PKR). This system utilizes two fixation pegs on the femoral component for fixation and alignment. To prepare for these features, a peg drill, drill guide, and drill through femoral trial are provided. The femoral Trial Drill Guide is attached to the Modular Handle and assembled into the holes on the articulation surface of the Femoral Trial. Using the appropriately sized Peg Drill (Small Drill for sizes 1-2, Large Drill for sizes 3-6), both holes are drilled. The Peg drill is advanced until the step on the drill makes contact with the front face of the Femoral Trial Drill Guide.
Worldwide Distribution - USA (nationwide) and the countries of Asia Pacific, Canada, Europe, Middle East and Africa (EMEA), and Japan
제품 설명
Tibial Alignment Handle || Triathlon Instruments || CAT #: 6541-2-807 || Nav Tibial Alignment Handle Triathlon Instruments || CAT #; 6541-2-808 || Howmedica Osteonics Corp. || 325 Corporate Drive || Mahwah, NJ 07430 || The tibial alignment handles Cat# 6451-2-807 and 6541-2-808 are part of the Triathlon Knee Instruments set. The alignment handle is used after the tibial resection portion of a total knee arthroplasty procedure. The alignment handle helps holding and orienting the tibial template and trial, which are used to estimate the size and assess the orientation of the final implant. The implant will provide the new bearing surface of the knee, replacing the damaged joint.
Worldwide: USA including states of MI and IL. and countries of Australia, China, New Zealand, Singapore, France, Germany, Italy, Portugal, Spain, Sweden and UK.
제품 설명
Triathlon MIS AP Sizer Body - Left and Right; Catalog Number: 6541-5-508- left; Catalog Number: 6541-5-509 - right, Stryker Orthopaedics, Mahwah, New Jersey
Worldwide: USA including states of MI and IL. and countries of Australia, China, New Zealand, Singapore, France, Germany, Italy, Portugal, Spain, Sweden and UK.
제품 설명
Triathlon MIS Femoral Adjustment Block;Catalog Number: 6541-5-601;Stryker Orthopaedics, Mahwah, New Jersey