Worldwide Distribution - US (nationwide) including DC and Puerto Rico, and in the states of AK, AL, AR. AZ, CA, CO, CT, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, MA, MD, ME, MI, MO, MS, NC, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, VA, WA, WI, WV, and WY and the countries of Austria, Belgium, Canada, Czech Republic, Denmark, Finland, France, Germany, Great Britain, Hong Kong, Hungary, Ireland, Italy, Luxembourg, Macedonia, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, and Ukraine.
제품 설명
Boston Scientific, Chariot ST-CCV Guiding Sheath, Sterilized using ethylene oxide: || Product Description Material Number (UPN) || Guiding Sheath 5F, 45 cm, ST, CC H74939277545110 || Guiding Sheath 5F, 45 cm, MP, CC H74939277545210 || Guiding Sheath 6F, 45 cm, ST, CC H74939277645110 || Guiding Sheath 6F, 45 cm, ST, TB H74939277645120 || Guiding Sheath 6F, 45 cm, MP, CC H74939277645210 || Guiding Sheath 6F, 45 cm, MP, TB H74939277645220 || Guiding Sheath 6F, 65 cm, ST, CC H74939277665110 || Guiding Sheath 6F, 65 cm, ST, TB H74939277665120 || Guiding Sheath 6F, 90 cm, ST, CC H74939277690110 || Guiding Sheath 6F, 90 cm, ST, TB H74939277690120 || Guiding Sheath 6F, 90 cm, MP, CC H74939277690210 || Guiding Sheath 6F, 90 cm, MP, TB H74939277690220 || Guiding Sheath 7F, 45 cm, ST, CC H74939277745110 || Guiding Sheath 7F, 45 cm, ST, TB H74939277745120 || Guiding Sheath 7F, 45 cm, MP, CC H74939277745210 || Guiding Sheath 7F, 45 cm, MP, TB H74939277745220 || Guiding Sheath 7F, 65 cm, ST, CC H74939277765110 || Guiding Sheath 7F, 65 cm, ST, TB H74939277765120 || Guiding Sheath 7F, 90 cm, ST, CC H74939277790110 || Guiding Sheath 7F, 90 cm, ST, TB H74939277790120 || Guiding Sheath 7F, 90 cm, MP, CC H74939277790210 || Guiding Sheath 7F, 90 cm, MP, TB H74939277790220 || Guiding Sheath 8F, 45 cm, ST, CC H74939277845110 || Guiding Sheath 8F, 45 cm, ST, TB H74939277845120 || Guiding Sheath 8F, 45 cm, MP, CC H74939277845210 || Guiding Sheath 8F, 65 cm, ST, CC H74939277865110 || Guiding Sheath 8F, 65 cm, ST, TB H74939277865120 || Guiding Sheath 8F, 90 cm, ST, CC H74939277890110 || Guiding Sheath 8F, 90 cm, ST, TB H74939277890120 || Product Usage: The Chariot Guiding Sheath is designed to perform as an introducer sheath for delivering interventional and diagnostic devices into the peripheral vasculature. The guiding sheath has a coiled shaft design and comes with a straight or preformed multipurpose tip shape. It is equipped with a cross-cut hemostatic valve or Tuohy-Borst adapter to prevent bleeding and a sidearm with a three-way stopcock to allow for flushing and introduction of contrast medium. It is packaged with a dilator to facilitate delivery over a guidewire. The guiding sheath can accommodate guidewires with diameters less than or equal to 0.038 in (0.97 mm). The outer surface of the guiding sheath has a hydrophilic coating from the distal tip to approximately 9 cm from the hub. The distal tip has a radiopaque marker band approximately 6 mm from the distal edge, to help with guiding sheath placement.
“We take a patient-first approach to assessing the applicability of every recall and communicate to regulatory bodies in all geographies where the recalled device is sold,” Boston Scientific said in a statement to ICIJ. “We have coordinated several recalls across many countries in a timely manner,” the company said, adding that it complies with all national laws, which can often vary and require different processes for reporting information or taking action on recalls. The company said it uses a rigorous and uniform process to take action on recalls and that “when we initiate a field action (e.g. recall, safety alert), every customer who has received an affected product receives a communication that includes a letter for the physician.”