ADVIA Centaur & ADVIA Centaur XP Immunoassay System (An in vitro diagnostic medical device (IVD)) 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Siemens Ltd Diagnostics Division 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2014-RN-00910-1
  • 사례 위험등급
    Class I
  • 사례 시작날짜
    2014-08-20
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Siemens healthcare diagnostics is conducting an urgent recall for product correction for the advia centaur and advia centaur xp immunoassay systems, regarding manually loaded sample racks that are improperly loaded or pushed too far on the sample entry queue during normal operation of the advia centaur and advia centaur xp immunoassay systems. pushing the sample racks may cause misreads of sample ids (sid) if the sample rack loading instructions are not followed exactly as described in the advia centaur or advia centaur xp operator’s guide.If a sample rack is manually pushed with a slight forward nudge to the entry position without placing it on the rack positioning guide, the barcoded tube sid can be assigned to different positions in the rack. this may lead to misreported results.
  • 조치
    Siemens Healthcare Diagnostics is advising the customers that when loading a sample rack, the user must ensure that the sample rack notch rests on the raised area of the sample entry queue and the system automatically moves the rack to the loading position. The raised guide ensures the sample rack is positioned correctly and will accurately scan each barcode as it enters the inprocess queue. Users are further advised not to push the sample racks into the system. During the next service visit, Siemens Healthcare Diagnostics service engineers will affix a label stating "Do not push sample rack" onto the system to reinforce the proper loading technique of the sample rack. This action has been closed-out on 5/08/2016.