Bayer Source Administration Sets (SAS) used with the Medrad Intego PET Infusion System 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Imaxeon Pty Ltd 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2015-RN-01195-1
  • 사례 위험등급
    Class II
  • 사례 시작날짜
    2015-12-07
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Bayer medical care inc. has identified that certain batches of the source administration sets (sas) used with the medrad intego pet infusion system may contain out-of-specification saline tubing and/or solvent occluding the radio pharmaceutical (rp) tubing.The inner diameter of the saline tubing is out-of-specification and may result in the system failing to position the dose correctly during extraction, potentially leading to a low measurement of the extracted dose or to a higher dose being extracted. the occluded sas tubing may impair the priming function and prompt an “rp prime failed. check sas and vial installation, then reprime.” error message. although unlikely, these situations may lead to procedure delay, false negative result due to incomplete dose, inaccurate dose reporting in the patient record, overdose of rp delivered and in rare situations additional radiation exposure for the operator.
  • 조치
    The sponsor Imaxeon is advising the users to inspect stock and quarantine the affected units prior to their return to the sponsor. There may be a delay in replacing the affected stock due to limited new inventory. This action has been clsoed-out on 29/08/2016.

Device

  • 모델명 / 제조번호(시리얼번호)
    Bayer Source Administration Sets (SAS) used with the Medrad Intego PET Infusion System [Catalogue Number INT CSS]Multiple batch numbers affectedARTG Number: 154205
  • Manufacturer

Manufacturer

  • 제조사 모회사 (2017)
  • Source
    DHTGA