Chemistry Calibrator used with ADVIA Chemistry Systems Direct Bilirubin Assay (DBIL_2). An in vitro diagnostic medical device (IVD). 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Siemens Healthcare Pty Ltd 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2016-RN-01374-1
  • 사례 위험등급
    Class II
  • 사례 시작날짜
    2016-10-18
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Siemens has confirmed that for several lots the currently assigned dbil_2 assigned calibrator values (acvs) may cause, on average, a positive proportional bias of approximately 41% on patient samples compared to the reference method for direct bilirubin measurement. quality control (qc) material is also affected by this issue. depending on the quality control concentrations and ranges used by the laboratory, quality control may not detect this issue. the positive bias may lead to an overestimation of direct bilirubin and the potential for further monitoring or confirmation of a potentially abnormal direct bilirubin finding during the assessment of liver dysfunction and/or during the investigation of jaundice. to correct the positive bias and restore alignment to the reference method, the acv for dbil_2 has been reassigned from 77 micromol/l to 55 micromol/l. all other analytes present in the chemistry calibrator meet product standards.
  • 조치
    Siemens is advising users to use the reassigned DBIL_2 ACVs for the affected Chemistry Calibrator lot numbers. In addition, laboratories should review the targets and ranges for quality controls used with the DBIL_2.

Device

  • 모델명 / 제조번호(시리얼번호)
    Chemistry Calibrator used with ADVIA Chemistry Systems Direct Bilirubin Assay (DBIL_2). An in vitro diagnostic medical device (IVD).ADVIA Chemistry CalibratorSiemens Material Number (SMN): 10312279 Lot Numbers: 680726 (exp. 2017-06), 680726A (exp. 2017-09), 680726B (exp. 2017-09), 680726C (exp. 2018-02), 680726D (exp. 2018-02)ARTG Number: 185171
  • Manufacturer

Manufacturer