ENDOEYE HD II Rigid Videoscope 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Olympus Australia Pty Ltd 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2017-RN-00197-1
  • 사례 위험등급
    Class I
  • 사례 시작날짜
    2017-02-09
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Olympus is extending the previous recall for product correction (tga ref.: rc-2015-rn-01141-1) from selected serial numbers to all serial numbers in the market. endoeye distal end can under certain circumstances become hot if the temperature sensor at the device’s tip is damaged (a mechanical breakage of the temperature sensor). although no patient or user injury has occurred as a result of this reported complaint, excessive heating of the endoeye distal end could result in patient or user injury.As part of the previous action selected serial numbers had the fog-free function disabled due to the backup mechanism (software) designed to detect and identify the failed temperature sensor was not functioning as expected, resulting in the potential for excessive heating if the sensor should fail. this was shortly followed by phase ii correction to replace the hardware (cable) and restore full functionality of the fog-free function.
  • 조치
    Users are advised to discontinue the use of any affected devices in their inventory. Olympus Field Service will schedule a time for to deactivate the fog-free function on the device. The visualisation of the devices will be unaffected and they can be immediately returned to routine use following correction. Customers will be notified once Olympus has concluded the technical investigation and established the permanent solution.

Device

  • 모델명 / 제조번호(시리얼번호)
    ENDOEYE HD II Rigid VideoscopeItem codes : WA50040A and WA50042A All serial numbersARTG Number: 121101
  • Manufacturer

Manufacturer