EXACTRAC 6.x (Image Guided RadiationTherapy Patient Positioning System) 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Brainlab Australia Pty Ltd 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2015-RN-00204-1
  • 사례 위험등급
    Class I
  • 사례 시작날짜
    2015-03-13
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Brainlab has internally detected an unexpected phenomenon for exactrac v.6.X that could occur when using the exactrac cone beam ct (cbct) module in combination with actively re-reconstructed cbct images of a subvolume from the original cbct volume. if a user-defined actively re-reconstructed cbct subvolume is imported into exactrac, exactrac cannot regard the position of this cbct subvolume correctly. if the center of this subvolume differs from the center of the original cbct volume, this leads to an erroneous calculation of patient shifts needed to move the patient to the planned treatment position. if the corresponding calculated shifts and rotations are applied with exactrac, the patient will be positioned incorrectly at the linac. if not detected by the user, the radiation treatment dose at the linac may be delivered to an unintended target position. if the deviation exceeds clinically acceptable limits, this could result in mistreatment, serious patient injury, or even death.
  • 조치
    Affected customers will be contacted starting August 2015 to schedule the installation of the software update In the interim, customers are advised to not use any actively re-reconstructed CBCT subvolumes from the Varian TrueBeam system with the Brainlab ExacTrac 6.x CBCT Import & Alignment Software module with immediate effect. Import exclusively original, not modified, CBCT volumes into ExacTrac to use for patient positioning. Continue to verify any ExacTrac CBCT-based correction using the ExacTrac X-ray verification and/or an external IGRT procedure as mandatory. This action has been closed-out on 1/06/2016.

Device

  • 모델명 / 제조번호(시리얼번호)
    EXACTRAC 6.x (Image Guided RadiationTherapy Patient Positioning System)Product Version Number: ExacTrac 6.0.0, 6.0.1, 6.0.2, 6.0.3, 6.0.4, 6.0.5; and v. 6.1.0ARTG Number: 121226
  • 의료기기 분류등급
  • Manufacturer

Manufacturer