Hospira labelled MedNet Medication Management Suite – with Plum 360 Infusion System 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Hospira Pty Limited 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2017-RN-01336-1
  • 사례 위험등급
    Class I
  • 사례 시작날짜
    2017-10-23
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
    ICU Medical, Inc. acquired from Pfizer in early 2017, Hospira Infusion Systems, the portion of Hospira dedicated to develop infusion pumps.
  • 데이터 추가 비고
  • 원인
    Icu medical has identified issues with hospira labelled mednet medication management suite versions 6.1 and 6.21 when used with plum 360 drug library management that occurs during the import of a plum 360 drug library.The mednet meds 6.1 and 6.21 programs, under certain conditions, can change the piggyback medication entry set settings for existing defined medication entries. this includes (a) whether a medication may be piggybacked and (b) whether an infusion may be interrupted by a piggyback.A change to a piggyback rule set could result in a delay initiating a therapy or interruption of an active infusion. this issue could also lead to mixing of two infusion solutions. if two mixed solutions are incompatible particulates could form or, if during a transfusion, a blood clot could form in the administration set. in rare circumstances, these conditions could lead to serious adverse health consequences.
  • 조치
    ICU Medical is advising users that the issue arises during an import of a Plum 360 drug library. Users who have performed an import of a Plum 360 drug library or have the need to do so should refer to the information provided to customers to confirm if the drug library is affected during the import. A correction to the issues will be addressed in MedNet version 6.3.