Powerheart G3 Defibrillation Electrodes (used in Powerheart G3 9300A, 9300E, 9300P, 9390A, and 9390E Automatic External Defibrillator (AEDs)) 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Cardiac Science Australia Pty Ltd 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2016-RN-00177-1
  • 사례 위험등급
    Class II
  • 사례 시작날짜
    2016-02-17
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Cardiac science has determined powerheart g3 defibrillation electrodes from lot no. 141125-02 may exhibit higher than expected electrical impedance over time. if electrode impedance becomes too high, the powerheart g3 automatic external defibrillator (aed) will fail the electrode self-test performed by the aed and it will not be rescue ready. specifically, if the aed fails the electrode self-test, the status indicator on the aed will be red and the aed will beep. this is standard behaviour when the impedance limit is exceeded. the aed will not be ready for use in a rescue in this state.The reported issue may result in failure to deliver shock therapy when needed and in the worst case could result in serious adverse health consequences, including injury or death. cardiac science is not aware of any instances in which lot no. 141125-02 electrodes failed to work at the time of therapy.
  • 조치
    The sponsor is advising users to identify the affected units and replace the electrodes with the replacement electrodes provided by the sponsor as per the instructions in the customer letter.