Target Nano Detachable Coil (used to obstruct or occlude blood flow in blood vessels) 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Stryker Australia Pty Ltd 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2016-RN-00772-1
  • 사례 위험등급
    Class I
  • 사례 시작날짜
    2016-06-09
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Stryker neurovascular has become aware that some units of the target nano detachable coils do not have the intended stretch resistance. the sutures inside the coil that provide stretch resistance may have been damaged during manufacturing which can lead to an increased occurrence of coil stretching.The most likely adverse health consequence from coil stretching is prolongation of the procedure, as the stretched coil needs to be removed from the patient and replaced. there is a potential of thrombus formation when the stretched coil is left exposed in the blood flow. additional intervention may be required to snare the stretched coil or pin it to the vessel wall with a stent if safe removal is not possible. this may result in thrombus or thromboembolism which can lead to stroke. there will be no long term adverse health consequence after a stretched coil is removed from the body.
  • 조치
    Stryker is advising users to inspect stock and quarantine any remaining affected units for return. This action has been closed-out on 03/03/2017.

Device

  • 모델명 / 제조번호(시리얼번호)
    Target Nano Detachable Coil (used to obstruct or occlude blood flow in blood vessels)Item Numbers: 542102, 542103, 542152, 542153, 542154, 543101, 543102, 543103, 543151, 543152, 543153, 543154, 544203, 544204, 544254, 544304, 544306, 544356, 545202, 545203, 545204, 545206, 545253, 545254, 545256, 545304, 545306, 545308Multiple lot numbers affectedARTG Number: 170214
  • 의료기기 분류등급
  • Manufacturer

Manufacturer

  • 제조사 모회사 (2017)
  • Source
    DHTGA