Thin and Radial Osteotome Blades Multiple Products and Model Numbers 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Smith & Nephew Pty Ltd 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2017-RN-00872-1
  • 사례 위험등급
    Class II
  • 사례 시작날짜
    2017-07-19
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Smith & nephew has identified a labelling error with specific models and batches of thin and radial osteotome blades. the expiration dates on the label exceed the actual validated expiration date of the outer sterile barrier packaging. affected devices have expiration dates based on a 10 year packaging shelf-life where the actual validated shelf life of the outer pouch packaging is 5 years. this could potentially result in the outside of the inner tray packaging being non-sterile, potentially contaminating the sterile field.The inner tray packaging is validated for a 10 year shelf-life and to date no adverse events have been associated with this issue.
  • 조치
    Smith & Nephew is requesting customers: 1. Immediately locate and quarantine affected devices; 2. If any of the recalled products could have been transferred from their hospital to another hospital please provide copies of the recall notice to all users; 3. The supplied acknowledgement form may be returned by email to RegulatoryAffairs.ANZ@smith-nephew.com or by fax on 1800 671 000 (Toll Free) 4. If you have affected product to return, Smith & Nephew representatives will be in contact with customers once the Recall Acknowledgement Form has been received to arrange for affected products to be returned. Please keep a copy of the completed Recall Acknowledgement form with any affected stock to be returned; and 5. Replacement products will be arranged once Smith & Nephew receive the Recall Acknowledgement Form.

Device

  • 모델명 / 제조번호(시리얼번호)
    Thin and Radial Osteotome Blades Multiple Products and Model NumbersMultiple Batch NumbersARTG Number: 140704
  • Manufacturer

Manufacturer