VITROS Immunodiagnostic Products HBsAg Controls. An in vitro diagnostic medical device (IVD). 의 리콜

Department of Health, Therapeutic Goods Administration에 따르면, 해당 리콜 는 Australia 에서 Ortho-Clinical Diagnostics 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    RC-2016-RN-00874-1
  • 사례 위험등급
    Class II
  • 사례 시작날짜
    2016-07-04
  • 사례 국가
  • 사례 출처
    DHTGA
  • 사례 출처 URL
  • 비고 / 경고
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • 데이터 추가 비고
  • 원인
    Ortho clinical diagnostics have received customer complaints that the signal/cutoff (s/c) results have increased when using the negative control. their investigation confirmed that results generated using these lots of negative controls had a positive shift in mean results (s/c) as the product approached its open-reconstituted 5 day limit. increased results (s/c) may also be observed with the positive control.This issue is isolated to vitros hbsag controls. patient sample results generated using vitros immunodiagnostic products hbsag/hbsag es reagents are not affected.
  • 조치
    Ortho Clinical Diagnostics is advising users to discontinue using and discard the affected lots. If you do not have an alternative unaffected lot, continue using the affected lot(s) following these instructions: - Control results must be within acceptable limits on the day of reconstitution (Day 1). - Store open-reconstituted vials frozen for up to 4 weeks. We recommend that you aliquot the open-reconstituted material prior to freezing so that multiple aliquots of the same vial can be used. - Upon receipt of replacement order, discard all remaining inventory. This action has been closed-out on 22/02/2017.

Device

  • 모델명 / 제조번호(시리얼번호)
    VITROS Immunodiagnostic Products HBsAg Controls. An in vitro diagnostic medical device (IVD).Product Code: 6800598Lot Numbers: 0860, 0870, 0880, 0890, 0908ARTG Number: 251956
  • Manufacturer

Manufacturer