Commercial Name: ENTERYX PROCEDURE KIT Registration ANVISA Nº 10341350381 -. Technical Name: Keratometer 의 안전성 경고

Agência Nacional de Vigilância Sanitária (ANVISA)에 따르면, 해당 안전성 경고 는 Brazil 에서 BOSTON SCIENTIFIC CORPORATION 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 사례 ID
    816
  • 날짜
    2005-10-11
  • 사례 국가
  • 사례 출처
    ANVISA
  • 사례 출처 URL
  • 비고 / 경고
    Brazilian data is current through June 2018. All of the data comes from Anvisa, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Brazil.
  • 데이터 추가 비고
    NOTE: BOSTON SCIENTIFIC DO BRASIL LTDA informs that in BRASIL this product was not marketed since it was only used in training with specialists from BOSTON SCIENTIFIC CORPORATION. The 18 physicians who participated in the training and hospitals involved will be notified in a statement. If you have any questions regarding this announcement, please contact Boston Scientific do Brasil Ltda, at 11-5502 8500
  • 원인
    Boston scientific corporation has chosen to initiate a voluntary recall of all enteryx products. according to information of the company this action is related to the technique of the injection procedure and not to the safety and effectiveness of the product when properly implanted.
  • 조치
    The company reports that it is collecting and analyzing an increasing number of data indicating that a transmural injection may occur despite the use of the fluoroscope throughout the procedure. Most transmural injections are recognized during the Enteryx procedure and or after the procedure through chest filming. He also reported that he was aware of 6 transmural injections that were not recognized during the procedure and immediately followed up. The most recent case involving a transmural injection resulted in a pleuropulmonary fistula. However, all these cases were recognized after 21 days of procedure. The possibility of a transmural injection through a vital organ is considered an unacceptable risk by Boston Scientific Corporation given the benign condition and other treatment options and as a result decided to collect the product from the market. If you have had any procedure with the Enteryx kit in the past month, we recommend that you follow up with your patient. Patients who had an unrecognized transmural injection had symptoms including epigastric pain, retrosternal pain (chest), respiratory tract infection (fever, cough, chest pain, difficulty breathing), pneumonia, syncopal episodes, and flank pain. If you feel that the presence of an unrecognized transmural injection needs to be evaluated, Boston Scientific Corporation will cover the additional costs of the imaging procedures required.

Manufacturer