Trade name: Cobas 6500 - u 601 eu 701. Technical name: Instrument for urinalysis. ANVISA registration number: 80712710007. Risk class: III. Model Affected: N / A. Serial numbers affected: See attached list on Anvisa portal - link: http://portal.anvisa.gov.br/informacoes-tecnicas13/-/asset_publisher/WvKKx2fhdjM2/content/alerta-2471-tecnovigilancia-roche-foco-cirurgico- The following table summarizes the results of this study: - illumina-sample incompatibility / 33868? p_p_auth = PAWpHtof & inheritRedirect; = false & redirect; = http% 3A% 2F% 2Fportal.anvisa.gov.br% 2Final-techniques13% 3Fp_p_auth% 3DPAWpHtof% 26p_p_id% 3D101_INSTANCE_WvKKx2fhdjM2% 26p_p_lifecycle% 3D0% 26p_p_state% 3Dnormal% 26p_p_mode% 3Dview% 26p_p_col_id% 3Dcolumn-3% 26p_p_col_pos% 3D1% 26p_p_col_count% 3D5 의 안전성 경고

Agência Nacional de Vigilância Sanitária (ANVISA)에 따르면, 해당 안전성 경고 는 Brazil 에서 Roche Diagnóstica Brasil Ltda.; Roche Diagnostics GmBH 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 사례 ID
    2471
  • 날짜
    2018-01-19
  • 사례 국가
  • 사례 출처
    ANVISA
  • 사례 출처 URL
  • 비고 / 경고
    Brazilian data is current through June 2018. All of the data comes from Anvisa, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Brazil.
  • 데이터 추가 비고
    Actions to be taken by the client / user: We request that you perform the procedure described below to verify the proper function of the systems. >>> Checks to be carried out by the operator: Please check the details panel of the result details screen, if the Sample ID, Rack ID and Rack position position) correspond to the Sample ID, Rack ID and Rack position physically inserted. Here's how: 1. Choose Routine> Manage Test Results 2. In the main panel, choose a sample entry. 3. In the details pane, choose the sample button at the top of the panel. If the Sample ID, Rack ID, and Rack position are not consistent with the physical condition, the test result should not be used and the sample reprocessed. If the problem occurs, contact Roche Technical Support (CEAC - 08007720295). >>> Verification of analyzer operation: Note: This test must be performed with bar code labels on the sample tubes, even if, in the normal routine, bar code labels are not used for sample identification. 1. Prepare 15 tubes labeled with bar codes and filled with water. 2. Place the tubes in 3 gray racks and place them in the rack tray. 3. Place the rack tray in the input buffer.  The measurement starts automatically. 4. After the measurements, verify that: a. Sufficient results are generated for all tubes and are displayed correctly. B. Sample ID (tube bar code), Rack ID and Rack position are displayed correctly according to the configuration of the 3 racks, especially double check the Rack ID. w. No sample ID (result) is missing, being displayed twice or pending in the order list. d. No alarm or error occurred. If all four tests (ad) have passed, the analyzer is in working condition. Otherwise, the analyzer should not be used and Roche Technical Support should be contacted for tube detection sensor adjustments (CEAC - 08007720295). If you wish to notify technical complaints and adverse events use the following channels: Notivisa: Notices of adverse events (AE) and technical complaints (QT) for products subject to Sanitary Surveillance should be made through the NOTIVISA System. To access the System, you must register and select the Health Professional option, if you are a liberal professional or the Institution / Entity option, if you are a professional of an institution / entity. Technovigilance System: Patient or citizen can notify through the Technovigilance System / SISTEC access through the link
  • 원인
    Roche diagnostica brasi informs customers and users of cobas u 601 and cobas u 701 about possible sample incompatibility within a rack. such a situation can only occur when using sample tubes labeled with bar codes.
  • 조치
    Field Action Code SBN-CPS-2017-026 triggered under the responsibility of the company Roche Diagnóstica Brasil Ltda. Will make field correction

Manufacturer