Trade name: Flowtron ACS900 System Technical Name: Member Compression System ANVISA Registration Number: 80259110105 Hazard Class: I Affected Model: Flowtron ACS900 System Affected Serial Numbers: All Serial Numbers / All Lots manufactured between 09/26 / 2014 and 12/20/2016, with software V1.099. 의 안전성 경고

Agência Nacional de Vigilância Sanitária (ANVISA)에 따르면, 해당 안전성 경고 는 Brazil 에서 MAQUET DO BRASIL EQUIPAMENTOS MEDICOS LTDA. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 사례 ID
    2320
  • 날짜
    2017-06-26
  • 사례 국가
  • 사례 출처
    ANVISA
  • 사례 출처 URL
  • 비고 / 경고
    Brazilian data is current through June 2018. All of the data comes from Anvisa, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Brazil.
  • 데이터 추가 비고
    The device may remain in use until modernization is performed, provided that the patient's limbs are frequently monitored and the dressing checked to ensure they are properly fitted to the patient and that deflation of the clothing is occurring regularly. It is also recommended that the LCD display of the pump be checked regularly to ensure it shows that the suits are inflating and deflating correctly. In the limited number of complaints, the LCD display was blank.
  • 원인
    It has been identified that in some cases the bomb will constantly transmit pressure to the suit without triggering the alarm. arjohuntleigh investigated the symptom found and concluded that the consistent flow of pressure to the suit without deflation can lead to a potential risk of injury to patients. arjohuntleigh has received a limited number of complaints related to this specific state. although this is likely to be remote, arjohuntleigh takes this issue seriously and advises you on the following steps: modernizing the acs900 pump for reviewing v.2000 software to ensure more resilient flowtron systems. the device may remain in use until modernization is performed, provided that the patient's limbs are frequently monitored and the dressing checked to ensure they are properly fitted to the patient and that deflation of the clothing is occurring regularly. it is also recommended that the lcd display of the pump be checked regularly to ensure it shows that the suits are inflating and deflating correctly. in the limited number of complaints, the lcd display was blank.
  • 조치
    Field Action Code FSN-SUZ-001-2017 triggered under the responsibility of the company MAQUET DO BRASIL EQUIPAMENTOS MEDICOS LTDA. Company will make correction in the field.

Manufacturer