Vascular Graft Prosthesis: (1) Distaflo Bypass, (2) Flexible with Small Bubble. Catalog No. (1) DF5006SC, DF5007SC, DF6006SC, DF6007SC, DF7006SC, DF8006SC; (2) F1006TWS, F3006TWSC, F310086TWS, F310086TWSC, F5006S, F5006SC, F5006TWS, F5006TWSC, F5008S, F5008TWS, F5008TWSC, F6006TWS, F6006TWSC, F7004TWS, F7005TWS, F7005TWSC, F7006S, F7006SC, F7006TWS, F7006TWSC, F7007TWS, F7007TWSC, F7008S, F7008SC , F7008TWS, F7008TWS, F7008TWS, F70N75TSC, F70N75TWS, F70T74TSC, F70T74TWS, F70T85TWS, F70T85TWS, F8006S, F8006SC, F8006TWS, F8007TWS, F8007TWS, F8007TWSC, F8008S, F8008SC, F8008TWS, F8008TWSC 의 안전성 경고

Agência Nacional de Vigilância Sanitária (ANVISA)에 따르면, 해당 안전성 경고 는 Brazil 에서 IMPRA Inc Div C R Bard Inc 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 사례 ID
    242
  • 날짜
    2000-12-29
  • 사례 국가
  • 사례 출처
    ANVISA
  • 사례 출처 URL
  • 비고 / 경고
    Brazilian data is current through June 2018. All of the data comes from Anvisa, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Brazil.
  • 데이터 추가 비고
    UNTIL THIS DATE DOES NOT CONSERT PRODUCT REGISTRATION IN BRAZIL
  • 원인
    The uk has demanded of impra to provide better instructions for use of the aforementioned prostheses to alert doctors in removing the small bubble and also demanded of impra withdrawing the product from the market to remedy the problem. the manufacturer initiated the recall of the defective product outside the united states by mail dated may 1999 and august 2000.
  • 조치
    Make sure that you have received the dated May 1999 and August 2000 correspondence from Impra. Identify and isolate any affected product from your inventory. ECRI recommends that you inform if any of the above units have been deployed in your institution and by whom. Tell the implant surgeon that the product is subject to removal. It is up to the cardiac surgeon to decide on the need for medical intervention in patients who have been implanted with the product. No action is necessary in the United States. For removal instructions, contact your local representative or directly with Impra at (1) (480) 894-9515 in the United States. ANVISA recommends that your establishment ensure that all patients who have these products in place are followed periodically and that this follow-up is documented in order to protect their implantable physicians and their establishment from a legal point of view. If it is necessary to replace the implants, if there is any difficulty in recovering from the manufacturer, immediately contact the ANVISA Technovigilance for arrangements.

Manufacturer

  • Source
    ANVSANVISA