HEARTSTART MRX DEFIBRILLATOR/MONITOR 의 리콜

Health Canada (via FOI)에 따르면, 해당 리콜 는 Canada 에서 PHILIPS ELECTRONICS LTD. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    42948
  • 사례 위험등급
    II
  • 사례 시작날짜
    2014-12-16
  • 사례 국가
  • 사례 출처
    HC
  • 비고 / 경고
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • 데이터 추가 비고
  • 원인
    Philips has become aware that the heartstart mrx defibrillator/monitor could reboot once in any operating mode if the following sequence occurs: 1. in service mode the status log* is cleared 2. prior to exiting service mode the device generates an entry in the status log. 3. service mode is exited. the heartstart mrx device is then in a state that could trigger a reboot at an indeterminate time potentially causing therapy to be interrupted or delayed. the heartstart mrx device will restart within 8 seconds. note: if a reboot occurs during clinical use current device settings and patient record are retained. *the status log is a tool accessed by service personnel. it includes entries for all messages logged during normal operating mode automated tests service and configuration mode and operational checks. the heartstart mrx defibrillator/monitor service manual instructs service personnel to clear the status log after successful completion of an operational check.

Device

  • 모델명 / 제조번호(시리얼번호)
    Model Catalog: M3536A (Lot serial: FOR MODEL M3536A:); Model Catalog: M3535A (Lot serial: FOR MODEL M3536A:); Model Catalog: M3535A (Lot serial: FOR MODEL M3535A:); Model Catalog: M3536A (Lot serial: US00100100 to US00578696); Model Catalog: M3535A (Lot serial: US00100100 to US00578696); Model Catalog: M3535A (Lot serial: US00100902 to US00576650); Model Catalog: M3536A (Lot serial: US00100902 to US00576650); Model Catalog: M3536A (Lot serial: FOR MODEL M3535A:)
  • 제품 설명
    HEARTSTART MRX DEFIBRILLATOR/MONITOR