INGENUITY CT SYSTEM 의 리콜

Health Canada (via FOI)에 따르면, 해당 리콜 는 Canada 에서 PHILIPS ELECTRONICS LTD. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    130773
  • 사례 위험등급
    II
  • 사례 시작날짜
    2015-02-17
  • 사례 국가
  • 사례 출처
    HC
  • 비고 / 경고
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • 데이터 추가 비고
  • 원인
    Philips has become aware of the following issues: - slab viewer longitudinal location issue - it is possible for the system to invert the sign (positive/negative) of the longitudinal position value displayed on an axial scan image. the following key events must take place for harm to occur: -the patient is placed in a "feet-first" orientation. -an interventional ct procedure is scheduled. -contrary to typical clinical practice a multi-planar reconstruction (mpr) is used for planning the interventional procedure (this issue only occurs in images produced using mpr). -a check scan is not performed (normal clinical practice indicates the use of a check scan before beginning an interventional procedure). -the needle tip placement is not confirmed as directed (this practice would prevent more than a minimal ingress of an intervention at an undesired location). - fast get ready issue - fast get ready incorrectly enabled during service procedures. - contrast annotation issue - contrast annotation incorrectly missing for some images when manual contrast was administered. - dot artifact issue - dot artifact present intermittently after startup. - heart rate update issue - heart rate measured value incorrectly remains constant for some heart rate change conditions. - doseright issue - doseright incorrectly enabled when the exam card specified disabling doseright. - tube heat issue - tube heat predictor fails to warn of overheat condition for long scans.

Device

  • 모델명 / 제조번호(시리얼번호)
    Model Catalog: 728326 (Lot serial: ALL); Model Catalog: 728323 (Lot serial: ALL)
  • 제품 설명
    INGENUITY CT SYSTEM