LABPRO SOFTWARE 의 리콜

Health Canada (via FOI)에 따르면, 해당 리콜 는 Canada 에서 BECKMAN COULTER CANADA L.P. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

의료기기에 문제가 생겼을 경우 제조사가 이를 바로잡거나 시장에서 회수하는 조치를 말한다. 회수(Recall)는 의료기기에 결함이 있거나, 건강에 위협이 되거나, 또는 결함도 있고 건강에도 위협이 될 경우에 발생한다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Recall
  • 사례 ID
    116480
  • 사례 위험등급
    II
  • 사례 시작날짜
    2015-07-21
  • 사례 국가
  • 사례 출처
    HC
  • 비고 / 경고
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • 데이터 추가 비고
  • 원인
    Beckman coulter has confirmed the following issues can be encountered when generating organism identifications in the microscan labpro information manager system from dried overnight gram negative panels processed on microscan autoscan-4 systems or read manually and entered into the labpro system. the use of dried overnight gram negative panels and the labpro software system on the walkaway system is not affected. some glucose non-fermenting organisms may display a color change (shade of yellow) in the glu suc and sor at 48 hours. when this occurs: - labpro software incorrectly allows the operator to manually edit the carbohydrate substrates (specifically glu suc and sor) when manually reading dried overnight gram negative (conventional) panels with an id hold status. - labpro software incorrectly overwrites the previously stored carbohydrate substrate results (specifically glu suc and sor) when reading dried gram negative overnight (conventional) panels which have an id hold status on the autoscan-4 system. - labpro software then incorrectly uses the fermenter identification substrates to calculate the biotype which may cause non-fermenters such as an acinetobacter species to be incorrectly identified as fermenters for example a shigella species.

Device

  • 모델명 / 제조번호(시리얼번호)
    Model Catalog: B1018-524 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 10361216 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3885 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3867 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3859 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3819 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3789 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3771 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3583 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3563 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 9800-3554 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 10807571 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 10638825 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 10638824 (Lot serial: Version 1.0 to Version 4.11); Model Catalog: 10638823 (Lot serial: Version 1.0 to Version 4.11); Model Ca
  • 제품 설명
    MICROSCAN LABPRO INFORMATION MANAGER SYSTEM