Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
The Parent Company and the Product Classification were added by ICIJ.
The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
데이터 추가 비고
원인
Retention of outdated information in an order set. it is possible that a change to an order set will not be saved in the current open care plan when the following work flow is utilized: 1-open either the care plan edit form or the care plan instance form and leave the form open. 2-select an order set that is part of the same care plan and make a change to the order set. this can be changed to the order set name and label or a change to the drug dose administration instructions etc. 3-the update made to the order set will not be saved in the current open care plan.