The adjustable mechanism in the strata device allows the physician to non-invasively adjust the valve's pressure/performance level (pl) using a magnetic adjustment tool included with the strata adjustment kit or with the stratavarius system. accumulation of biological debris within the valve adjustment mechanism may inhibit the free rotation of the valve magnet when exposed to 3t mri and may become reverse polarised. this may result in discrepancies between the pressure level readings on the strata indicator tool or stratavarius system.
Model Catalog: 44420 (Lot serial: >100 nunbers contact mfg); Model Catalog: 46836 (Lot serial: >100 nunbers contact mfg); Model Catalog: 42355 (Lot serial: >100 numbers contact mfg); Model Catalog: 42866 (Lot serial: >100 nunbers contact mfg); Model Catalog: 42856 (Lot serial: >100 nunbers contact mfg); Model Catalog: 44430 (Lot serial: >100 nunbers contact mfg); Model Catalog: 44421 (Lot serial: >100 nunbers contact mfg); Model Catalog: 46871 (Lot serial: >100 nunbers contact mfg); Model Catalog: 46876 (Lot serial: >100 nunbers contact mfg); Model Catalog: 46881 (Lot serial: >100 nunbers contact mfg); Model Catalog: 46886 (Lot serial: >100 nunbers contact mfg); Model Catalog: 27820 (Lot serial: >100 nunbers contact mfg); Model Catalog: 27821 (Lot serial: >100 nunbers contact mfg); Model Catalog: 46635 (Lot serial: >100 nunbers contact mfg); Model Catalog: 42365 (Lot serial: >100 numbers contact mfg); Model Catalog: 27818 (Lot serial: >100 nunbers contact mfg); Model Catalog: 27819 (Lot serial: >100 nunbers
제품 설명
Strata NSC Lumboperitoneal Shunt Kit;Strata Burr Hole Shunt Assembly;Strata Valve;Strata II Valve;Strata II Unitized Shunt Kit;Strata NSC Burr Hole Shunt Assembly;Strata II Shunt Assembly with Bioglide;Strat II Snap Shunt Assembly;Strata II Valve with Bio
“If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.