Advanced Perfusion System 1 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Terumo Cardiovascular Systems Corporation 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-12-24
  • 사례 출판 날짜
    2012-12-24
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: terumo advanced perfusion system 1 medical device manufacturer, terumo cardiovascular systems corporation, has issued a medical device safety alert concerning base for terumo advanced perfusion system 1 (catalogue number: 801763). terumo cardiovascular systems (cvs) has become aware of a remote possibility that terumo advanced perfusion system 1 could experience a spontaneous loss of system power. terumo cvs is issuing a safety notice because the user’s manual for the terumo system 1 does not provide user instruction for responding to such an event. according to terumo cvs, five reports of spontaneous power loss for the terumo system 1 have been received between 2003 and 2012: in all reports, the systems lost full power and did not switch to battery backup. this occurred without warning. in one report, the system re-booted automatically after approximately 30 seconds. in the remaining reports, the system regained power after the user toggled the main power switch. in all reports, the user was able to establish full function for the remainder of the case and the system did not exhibit the malfunction again. the complete loss of system power would result in loss of all patient support functions, including arterial blood flow, myocardial protection, venting and suction capabilities, safety systems, system alarms and system information. depending on the response of the clinical team and the availability of backup equipment, a prolonged lack of such support could result in death or serious injury. the manufacturer supplemented that the potential patient injuries range from no injury to varying degrees of neurologic dysfunction, cardiac dysfunction due to inadequate myocardial protection, end organ dysfunction, or death in the case of an extended period of no flow. in the event a user experiences a spontaneous loss of power without the automatic initiation of the battery backup system, terumo cvs recommends: the user first ensures that the entire system has lost power by checking the central control monitor (ccm), the local pump displays, the led indicators on the modules, and the battery status indicator on the front of the system. once certain the entire system has lost power, turn the main power switch on the front panel to the “off” position then to the “on” position. contact terumo cvs customer service immediately upon conclusion of the case. according to the local supplier, the affected products have not been distributed in hong kong. if you are in possession of the products, please contact your supplier for necessary actions. posted on 24 december 2012.

Device

Manufacturer