allura xper systems - allura xper fd10 , allura xper fd10/10 , allura xper fd20, allura xper fd20/10, allura xper fd20/20 and allura cv20 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Philips Healthcare 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2011-08-04
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Field safety notice: philips allura xper systems - allura xper fd10 (f/c), allura xper fd10/10 (incl. or table), allura xper fd20, allura xper fd20/10, allura xper fd20/20 and allura cv20 philips healthcare has issued a field safety notice to the customers of allura xper systems. investigation of field problems on the allura xper systems showed that there is a problem related to the harddisk firmware. the hard disk drive itself is working fine but the used firmware suffers from an incorrect incrementing smart counter. this might result in a very high “raw read error” count which will lead in a so called “smart trip” and subsequently will take the hard disk drive offline. consequently the system might intermittently freeze. this can vary from several seconds up to one minute. if during a procedure the system intermittently freezes for several seconds and up to one minute, the system does not generate x-ray anymore and no geometry movement is possible during this period of time. if this happens during a critical phase in a procedure this might lead to a disturbance in the procedure and a possible injury to the patient. this intermittent image freeze / system freeze is not foreseeable or recognizable by the user. the manufacturer recommended customers not to reboot or take any other actions until the system proceeds on its own, because this could slowdown the systems automatically recovery. the manufacturer will provide users a cd with the correct firmware and an installation procedure to implement the corrective actions. according to the local supplier, hong kong is affected. the local supplier is following up the issue with its customers. if you are in possession of the affected product, please contact your supplier (hotline: 2821-5473) for necessary actions.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: [4 Aug 2011] Philips Allura Xper Systems - Allura Xper FD10 (F/C), Allura Xper FD10/10 (incl. OR table), Allura Xper FD20, Allura Xper FD20/10, Allura Xper FD20/20 and Allura CV20