Artis/Evosys Dialysis System equipped with SW 8.15.06 and 8.33.02 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Gambro 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2015-01-14
  • 사례 출판 날짜
    2015-01-14
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: gambro artis/evosys dialysis system equipped with sw 8.15.06 and 8.33.02 medical device manufacturer, gambro, has issued a field safety notice concerning artis/evosys dialysis system equipped with sw 8.15.06 and 8.33.02. the manufacturer reminds users of the possibility that foam may be formed in the venous blood circuit when the extracorporeal circuit is primed using on-line priming. the priming volume specified in the operator’s manual and in the dialyzer instruction for use may not be sufficient to completely eliminate any air trapped in the dialyzer fibres. when this occurs, some foam may be created in the venous circuit during patient connection and during the first few minutes of treatment. the condition is visible to the operator. the potential hazard would be presence of some foam in the venous patient line. the air bubble detection system is designed to stop the blood pump when macro bubbles greater than 20 μl are detected. the presence of operator also reduces the risk of foam reaching the patient. according to the local supplier, only the artis dialysis system is distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 14 january 2015.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Gambro Artis/Evosys Dialysis System equipped with SW 8.15.06 and 8.33.02
  • Manufacturer

Manufacturer