BD Vacutainer EDTA tubes and BD Vacutainer Lithium Heparin Green Top Tubes 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Becton Dickson and company 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2018-03-23
  • 사례 출판 날짜
    2018-03-23
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: becton dickson bd vacutainer edta tubes and bd vacutainer lithium heparin green top tubes the united states food and drug administration (fda) has issued a medical device safety alert concerning bd vacutainer edta tubes and bd vacutainer lithium heparin green top tubes, manufactured by becton dickson and company (bd). the affected products are listed below: vacutainer edta lavender top tubes (catalogue numbers: 364300, 366401, 366450, 366643, 367835, 367841, 367844, 367856, 367861, 367862, 367863, 368021, 368047, 368054, 368661) vacutainer edta tan top tubes (catalogue numbers: 367855) vacutainer edta pink top tubes (catalogue numbers: 367842, 367899, 368049, 368589) vacutainer lithium heparin green top tubes (catalogue numbers: 366664, 367884, 367886, 368040, 366667, 367880) lot numbers: all lots within expiry based on data provided by bd (the manufacturer), the fda has concluded that one of the contributing factors to the inaccurate leadcare test results is the chemical composition of the rubber stoppers of certain blood collection tubes. the fda requested the manufacturer to conduct studies to assess the accuracy of magellan’s leadcare testing systems when used with venous blood collected into bd venous blood tubes. the fda concluded that the studies performed by the manufacturer were robust and showed that there was a significant chance of incorrect results with magellan’s leadcare tests when used with venous whole blood collected in certain bd blood tubes. upon further investigation, the manufacturer determined that the affected tubes' rubber stoppers contain a chemical called thiuram that can release reactive gases, carbon disulfide (cs2) and carbonyl sulfide (cos), which can dissolve into the blood sample and bind tightly to lead particles. this chemical reaction makes it difficult for the magellan lead tests to detect the correct amount of lead in the sample. the fda also requests the manufacturer to conduct testing to determine whether clinical laboratory tests other than the magellan lead tests are affected by the thiuram chemical interference. based on the results of the studies to date and the understanding of the mechanism of the interference, the fda does not believe there is evidence showing that other clinical laboratory test results are impacted by the thiuram chemical interference at this time. the manufacturer is notifying their customers about this information. according to the fda thiuram may be used by manufacturers other than bd to manufacture rubber stoppers for blood collection. the fda is following up with manufacturers of blood tubes marketed in the u.S. to investigate this issue. the fda continues to recommend that venous samples not be used with magellan lead tests. this recommendation applies to all venous blood collection tubes. capillary blood may continue to be tested with the magellan lead tests. for details, please refer to the fda website: https://www.Fda.Gov/medicaldevices/productsandmedicalprocedures/invitrodiagnostics/labtest/ucm566188.Htm if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 23 march 2018.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Becton Dickson BD Vacutainer EDTA tubes and BD Vacutainer Lithium Heparin Green Top Tubes
  • Manufacturer

Manufacturer