C-Series High Energy Linear Accelerator 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Varian Medical Systems 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2014-06-24
  • 사례 출판 날짜
    2014-06-24
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: varian medical systems c-series high energy linear accelerator medical device manufacturer, varian medical systems, has issued a medical device safety alert concerning its c-series high energy linear accelerator, [affected models: novalis tx, trilogy, trilogy tx, clinac ix, clinac cx, clinac 2100 c/d, clinac 2300 c/d, clinac dx, clinac 21 ex, clinac 23 ex 6 mv configurations only]. the manufacturer has seen a trend in reports of unexpected decrease in beam output in c-series high energy linear accelerators for 6mv photon treatment mode. this failure mode in the target only affects the 6 mv photon treatment modes (6srs, 6fff, and 6x). no other energies are affected. the manufacturer has determined the cause of the unexpected variations in beam output to be degradation of the 6mv target. specifically, the effects of modern, highly modulated treatment modes can create high levels and frequency of stress cycles in the targets particularly if the beam spot size is small. this can lead to the target’s deterioration and failure at an accelerated rate resulting in a rapid change in the beam output and symmetry. specifically:- the photon generation, or bremsstrahlung yield, decreases as fewer electrons are converted to photons in the target, and; due to a resulting escape of primary electrons the output of photons, as measured by the ion chamber, might appear to be constant, but the actual photon output is decreasing according to the local supplier, the affected products were distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 24 jun 2014.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Varian Medical Systems C-Series High Energy Linear Accelerator