Ceiling Supply Units [CSU 603X/ 803X] 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Draeger Medical GmbH 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2013-08-09
  • 사례 출판 날짜
    2013-08-09
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: draeger ceiling supply units [csu 603x/ 803x] medical device manufacturer, draeger medical gmbh, has issued a medical device safety alert concerning ceiling supply units (csu) [model: csu 603x/ 803x] with year of construction between 1997 and 2003. in the course of the manufacturer’s international market observations, there were cases in which the drive screw in the motor unit, which lifts and lowers the lower lift arm, broke. as a result, the lift arm fell down approx. 60 cm (23.6 inches). if the drive screw breaks, personnel standing under the csu may be injured or objects damaged. an inclined alignment of the motor unit has been identified the root cause for the drive screw breaking. in the cases in question, this inclined alignment was caused by: blocked joint axes or insufficient symmetry of the support plate (incorrect/inclined alignment of the lift arm) or previous mechanical damage due to excessive dynamic load (collision of the arms, clamping the arms into window lintels etc.). this can result in a deformation of the carrier plate and thus cause a fatigue fracture of the drive screw. these three potential causes can be detected during maintenance. additionally, the performance of regular maintenance can prevent this type of failure. according to the information in the instructions for use, ceiling supply units must be maintained in regular intervals. this is the only way to ensure safety and reliability during the period of use. the manufacturer advises a further inspection of the location of the motor unit according to the test instructions they given together with the field safety notice if users had no service contract with the company. if users identify an inclined alignment of the motor unit, they should replace it as soon as possible. in such a case, special care should be taken that no persons or objects are under the media head until the motor unit has been replaced. according to the local supplier, the affected products were distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 9 august 2013.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Draeger Ceiling Supply Units [CSU 603X/ 803X]
  • Manufacturer

Manufacturer