Cemented, Polished and Cobalt Chromium Alloy Hip Stems 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 DePuy 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-05-03
  • 사례 출판 날짜
    2012-05-03
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: depuy cemented, polished and cobalt chromium alloy hip stems it comes to our attention that medical device manufacturer, depuy (a johnson & johnson company) has issued a field safety notice concerning depuy cemented, polished and cobalt chromium alloy hip stems. in 2007, depuy issued a letter to ultima tps cemented polished cobalt chromium (cocr) hip stem users in the united kingdom (uk) to inform them of a potential association between extensive peri-prosthetic soft tissue necrosis and hip stem implantation with the ultima metal-on metal (mom). following research activities undertaken by depuy, it was concluded that when used in combination with a mom articulation of an all metal type, depuy’s cemented, polished, cocr femoral hip stems, including the depuy g2 and fjord cemented femoral hip stems could potentially exhibit corrosion of the polished surfaces which are within the cement mantle. this corrosion may in turn lead to an increased incidence of peri-prosthetic soft tissue necrosis. therefore, depuy advises against the implantation of the following configuration: depuy’s cemented, polished, cocr alloy femoral hip stems combined with mom articulation. according to the local supplier, ultima tps, depuy g2 and fjord cemented femoral hips stems have not been distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted 03 may 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: DePuy Cemented, Polished and Cobalt Chromium Alloy Hip Stems
  • Manufacturer

Manufacturer