CoreValve AccuTrak Delivery Catheter System 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Medtronic 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2013-11-28
  • 사례 출판 날짜
    2013-11-28
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: medtronic corevalve accutrak delivery catheter system medical device manufacturer, medtronic inc has issued a medical device safety alert concerning corevalve accutrak delivery catheter system (dcs). models dcs-c4-18fr and dcs-c4-18fr-23 are affected. as of 31 october 2013, medtronic has received 38 reported nose cone separation events (0.08 percent of implant procedures). 5 of these reported events (0.01 percent of implant procedures) led to the need for surgical intervention. a thorough review and investigation of the reported events has identified that a majority of these reported events occurred in situations cautioned against in current labeling. in addition, medtronic has determined that the following situations can lead to nose cone separations: using the corevalve accutrak dcs to retrieve (remove) a partially deployed valve. removing the corevalve accutrak dcs from the patient, after valve deployment, without fully closing the corevalve accutrak dcs capsule. continuing to pull on the corevalve accutrak dcs if increased resistance is felt at the vessel introducer, the introducer’s hemostatic valve, or other structure during corevalve accutrak dcs retrieval. to reduce the occurrence of nose cone separations, medtronic is modifying the instructions for use and training materials for corevalve accutrak dcs models dcs-c4-18fr and dcs-c4-18fr-23. meanwhile, users are advised to consider the following recommendations during the corevalve implant procedure: while the dcs is in the patient, ensure the guidewire is extending from the nose cone, and do not remove the guidewire from the catheter while the catheter is inserted in the patient. once deployment is initiated, retrieval (removal) of the bioprosthesis from the patient is not recommended. partial repositioning, if needed, should be followed per the ifu guidance. before dcs removal, ensure the capsule is closed. if the capsule does not close properly, gently rotate the catheter clockwise (<180°) and then counterclockwise (<180°) until the capsule closes. if there is increased resistance when removing the dcs through the introducer sheath, do not force passage as increased resistance may indicate a problem and may result in damage to the device and/or harm to the patient. if the cause of resistance cannot be determined or corrected, remove the catheter and introducer sheath as a single unit over the guidewire, and inspect the catheter. according to the local supplier, the affected products were distributed to hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 28 november 2013.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Medtronic CoreValve AccuTrak Delivery Catheter System
  • Manufacturer

Manufacturer

  • 제조사 모회사 (2017)
  • 제조사 의견
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    DH