Cranial Navigation System – Standard Cranial Reference Array 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 BrainLab AG 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-08-14
  • 사례 출판 날짜
    2012-08-14
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: brainlab cranial navigation system – standard cranial reference array the medicines and healthcare products regulatory agency (mhra), united kingdom posted a medical device safety alert concerning cranial navigation system – standard cranial reference array manufactured by brainlab ag. manufacturing tolerances of the arrays influence the actual position of its marker spheres. the differences between the individual arrays are supposed to be very small, not significantly affecting navigation accuracy when the unsterile array is exchanged with the sterile array during surgery. however, according to the manufacturer, there are specific pairs of arrays that might add an inaccuracy of more than 1 mm to the registration result during the exchange due to the combination of their tolerance limits. this effect could potentially cause an inaccurate display of instruments by the navigation system in the region of interest, compared to the actual patient anatomy. if these inaccuracies are not detected by user verification of navigation accuracy as described in the user manual, this could lead to serious injury or ineffective treatment of the patient. customers are advised to remove the affected products from clinical use. for details, please refer to the following mhra website: http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/index.Htm if you are in possession of the affected product, please contact your supplier for necessary actions. posted on 14 august 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: BrainLab Cranial Navigation System – Standard Cranial Reference Array