Disposable paediatric ventilation circuit for Oxylog Transport Ventilators 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Draeger Medical GmbH 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2016-05-26
  • 사례 출판 날짜
    2016-05-26
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: draeger disposable paediatric ventilation circuit for oxylog transport ventilators medical device manufacturer, draeger medical gmbh, has issued a medical device safety alert concerning its disposable paediatric ventilation circuit ventstar oxylog 3000f (p) 190 [part number: 5704964; date of manufacture: up to 03-2016] for oxylog 3000 and oxylog 3000 plus transport ventilators. during the course of routine internal testing, the manufacturer detected isolated leakages at the check valve (one way valve of the inspiration branch) of the affected device. further detailed investigations have shown that the check valve functions properly with no leak observed at positive end-expiratory pressures above 5 mbar / cmh2o. the problem only occurs at peep values below 5 mbar / cm h2o. according to the manufacturer, leakage at the check valve can result in patient’s exhaled gas entering into the breathing circuit, which could lead to the rebreathing of the exhaled gas with reduced oxygen concentration for the patient. the manufacturer recommends that the users immediately inspect any stock and dispose of any product (part number 5704964) with a date of manufacture up to and including 03-2016. if it is necessary to use affected ventilation circuits prior to receiving replacements, the manufacturer recommends only using the circuit at a peep setting of > 5 mbar / cmh2o, provided that a peep setting of > 5 mbar / cmh2o is appropriate from a medical point of view. additionally, the manufacturer recommends for this use case the use of external co2 monitoring by means of a paediatric cuvette and co2 mainstream sensor. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected product, please contact your supplier for necessary actions. posted on 26 may 2016.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 의료기기 분류등급
  • 제품 설명
    Medical Device Safety Alert: Draeger Disposable paediatric ventilation circuit for Oxylog Transport Ventilators
  • Manufacturer

Manufacturer