eclipse treatment planning systems [versions 8.9 & 10.0] 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Varian Medical Systems 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-08-31
  • 사례 출판 날짜
    2012-08-31
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: eclipse treatment planning systems [versions 8.9 & 10.0] medical device manufacturer, varian medical systems, has issued a medical device safety alert concerning eclipse treatment planning systems [versions 8.9 and 10.0]. according to the manufacturer, an anomaly that has been identified with the eclipse treatment planning system where an outdated assigned hounsfield unit [hu] value can be used for dose calculation when the clock on the eclipse client workstation is not synchronized with the database/system server. when the eclipse client workstation clock is running behind the clock on the database/system server, it is possible that a change to the assigned hu value for a structure does not invalidate the density image stored in the cache, and for the subsequent dose and monitor unit [mu] calculation to be based on the outdated hu assignment. the resultant mus may be higher or lower than expected, dependent on the specific hu assignments. treatment of the patient using these values can therefore lead to under- or over-dose. for this situation to arise, the eclipse workstation client clock must show an earlier time than that on the database/system server clock (for example, client time shows 09:05:17, server time shows 09:13:47). the following activities must take place on that client workstation for the discrepancy to occur: an hu value must be assigned to one or more structures. the plan must be saved. this places a timestamp (s) on the dcf cache files, where s is the current server time. the dose is then calculated. the dose is cleared (for example by resetting the calculation area). then either a new hu value is assigned to a structure, or an existing hu value is modified. before the current client time reaches the time the server showed at s, the plan must be recalculated. the calculation will then be based on the outdated hu value that existed at time s. an independent verification of the mus will highlight the discrepancy. the manufacturer advises all users to ensure that the workstation clock is synchronized with the database/system server clock. according to the manufacturer, the affected products were distributed in hong kong. if you are in possession of the affected product, please contact your supplier for necessary actions. posted on 31 august 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Eclipse Treatment Planning Systems [Versions 8.9 & 10.0]
  • Manufacturer

Manufacturer