EnVeo R Loading System 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Medtronic 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2015-07-16
  • 사례 출판 날짜
    2015-07-16
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: medtronic enveo r loading system medical device manufacturer, medtronic, has issued a medical device safety alert concerning enveo r loading systems for specific lot numbers of model numbers due to particulate being observed in a small number of cases. the affected devices are identified as follows: model numbers: ls-enveor-23, ls-enveor-2629, ls-enveor-23-c, ls-enveor-2629-c lot numbers: 0007266413, 0007408862, 0007462905, 0007515698, 0007573785, 0007332504, 0007408865, 0007476215, 0007515700, 0007573788, 0007332506, 0007408867, 0007476217, 0007515703, 0007573791, 0007332508, 0007408869, 0007476219, 0007522595, 0007579940, 0007332510, 0007428258, 0007482219, 0007522598, 0007579944, 0007343321, 0007428260, 0007482222, 0007522600, 0007579948, 0007343324, 0007428263, 0007482226, 0007522603, 0007579951, 0007343327, 0007435169, 0007486826, 0007530963, 0007592664, 0007350825, 0007439358, 0007492356, 0007530973, 0007592666, 0007350837, 0007439360, 0007495691, 0007537892, 0007592669, 0007354245, 0007439362, 0007495694, 0007537894, 0007592672, 0007366949, 0007456292, 0007495696, 0007569474, 0007598984, 0007369883, 0007456298, 0007508883, 0007569477, 0007254814, 0007393098, 0007462901, 0007508885, 0007569482, 0007354113, 0007393101, 0007462903, 0007508891, 0007573778 through 6 july 2015, the manufacturer has received eight reports related to this issue out of 7,347 potentially affected units. two were reported as particulate being observed in packaged kits and six were reported as particulate being observed in the loading bath during valve loading. according to the manufacturer, presence of particulate in the enveo r loading system has the potential to be transferred to the transcatheter aortic valve (tav) and released into the patient’s vasculature after deploying the tav. if this were to occur, potential harms may include embolism into the bloodstream. the manufacturer advises customers to immediately quarantine the unused potentially affected product form their inventory and return them to the manufacturer. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 16 july 2015.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 의료기기 분류등급
  • 제품 설명
    Medical Device Safety Alert: Medtronic EnVeo R Loading System
  • Manufacturer

Manufacturer

  • 제조사 모회사 (2017)
  • 제조사 의견
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    DH