Etest PIP/TAZO/CON‐4 PTC 256 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 bioMérieux 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2015-11-27
  • 사례 출판 날짜
    2015-11-27
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: biomérieux etest pip/tazo/con‐4 ptc 256 medical device manufacturer, biomérieux, has issued a medical device safety alert concerning its etest pip/tazo/con‐4 ptc 256. [product reference numbers: 412434, 412433, 521418 and 521458] based on a low minimum inhibitory concentration (mic) report from the field, the manufacturer initiated a complaint investigation (pr 929981) to confirm product performance and determine root cause. as a result of the investigation, the following was identified: isolates (enterbacteria strains) were tested with agar dilution and broth micro dilution reference method: using eucast breakpoints (mic< or =8: susceptible; mic>16: resistant), etest pip/tazo showed a higher frequency of erroneous results, false susceptible results, when comparing to the referenced method (broth-micro dilution). performance using clsi breakpoints (compared to broth micro dilution referenced method) was similar to eucast. in conclusion, the data analysis demonstrates that the etest piperacillin/tazobactam performance has shifted when compared to the published performance characteristics. according to the manufacturer, the risk to patients as a result of the etest pip/tazo/con‐4 ptc 256 performance shift is the potential for reporting erroneous results for piperacillin/tazobactam; specifically false susceptible results. this risk may lead to medical intervention for the patient because the erroneous result could negatively influence the selection of antibiotic therapy. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 27 november 2015.