FL14E Rose Bed 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Stryker 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2013-05-08
  • 사례 출판 날짜
    2013-05-08
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: stryker fl14e rose bed health canada has issued a medical device safety alert concerning fl14e rose bed, manufactured by stryker. stryker canada, in collaboration with health canada, is providing the safety notice to inform users on the risk of siderail collapse with the hospital bed - fl14e rose bed. it was reported that the siderail may appear latched in the upright position when it is not fully locked in place and may unexpectedly collapse if a pressure is applied on it. this failure has resulted in bruises and/or lacerations to patients who are leaning against the siderail when it collapses. additionally, the siderail may not effectively prevent a patient from rolling or falling off the bed. seven incidents, including three cases resulting in injuries to patients, were reported in canada. the notice also attaches an addendum to the maintenance manual which provides procedures for annual maintenance to all three siderail types (full length, three-quarter length or half-length) as well as guidance on when and how to properly adjust the beds. it also provides the following advice to affected users: there is a risk for the siderail to unexpectedly collapse as it appears to be latched in the upright position when it is not fully locked in place. this can result in bruises and/or lacerations to patients. also, the siderail may not adequately prevent a patient from rolling or falling off of the bed. personnel are advised to locate the fl14e rose beds in their facility, ensure that the siderails have been inspected and adjusted using the addendum as attached to the safety notice and to continue to routinely inspect the siderails and functionality. personnel are reminded to raise the siderail by its centre to prevent a premature wear of the siderail latching mechanism, which can contribute to siderail failure. for details, please visit the following health canada website: http://healthycanadians.Gc.Ca/recall-alert-rappel-avis/hc-sc/2013/ 28927a-eng.Php if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 08 may 2013.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Stryker FL14E Rose Bed
  • Manufacturer

Manufacturer

  • 제조사 모회사 (2017)
  • Source
    DH