Gemstar Docking Station 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Hospira Inc 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2013-11-05
  • 사례 출판 날짜
    2013-11-05
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
    ICU Medical, Inc. acquired from Pfizer in early 2017, Hospira Infusion Systems, the portion of Hospira dedicated to develop infusion pumps.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: hospira gemstar docking station the medicines and healthcare products regulatory agency (mhra), united kingdom (uk) posted a medical device safety alert concerning gemstar docking station (list numbers 13075-xx-07, 13075-xx-09) manufactured by hospira inc. two problems may occur when the above gemstar docking station is used with gemstar pumps and external battery pack. first, when the docking station is used with a gemstar phase 3 infusion pump (list numbers 13000-xx, 13100-xx or 13150-xx) the pump may fail to power up while connected to the docking station. second, when the docking station is used with a gemstar phase 4 infusion pump (list numbers 13086-xx, 13087-xx or 13088-xx) and an external battery pack (list number 13073-xx) the pump may display error code 11/003 indicating excessive input voltage from the external sources. the 11/003 error code will stop infusion if it occurs while an infusion is in progress. as a delay of therapy may occur which can result in patient injuries, hospira advises users to: use two fresh internal aa batteries if a failure to power up occurs. remove the battery pack prior to installing the pump into the docking station in order to mitigate the potential for an 11/003 error code. report to hospira if their pumps experience a failure to power up or an 11/003 error code. for details, please visit the following mhra website: http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/index.Htm if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 5 november 2013.