Hamilton-C2 (PN 160001) and Hamilton-C3 (PN 160005) Ventilator Unit 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Hamilton Medical AG 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2017-09-05
  • 사례 출판 날짜
    2017-09-05
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: hamilton medical ag hamilton-c2 (pn 160001) and hamilton-c3 (pn 160005) ventilator unit the medicines and healthcare products regulatory agency (mhra) of the united kingdom (uk) has issued a medical device safety alert concerning hamilton-c2 (pn 160001) and hamilton-c3 (pn 160005) ventilator unit, manufactured by hamilton medical ag. the analysis of a customer complaint has identified an issue relating to the battery charge of the hamilton-c2/c3 batteries after a usage of two and a half years. the battery fuel gauge may indicate a higher battery charge as to what is available. the technical failure 444001"low battery" high priority alarms are triggered, alerting the operator both acoustically and visually before entering ambient mode. according to the manufacturer, when batteries are depleted, the operator is alerted by high priority alarms and if the ventilator is not immediately connected to an ac power outlet, the ventilator will switch into ambient mode. the alarm is triggered in every case to alert medical staff. the affected users are instructed to take the following actions:- the operator should make themselves familiar with the batteries' manufacturing date and react in time if battery is more than two years old. any battery with a manufacturing date to two years prior to the current date should be replaced. if the battery is less than two years old, return battery to slot, pushing until clip clicks into place, locking in the battery. use a screwdriver to lock metal clip back into place over battery. close battery door. for details, please refer to the mhra website: https://www.Gov.Uk/drug-device-alerts/field-safety-notice-29-august-to-1-september-2017 if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 5 september 2017.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Hamilton Medical AG Hamilton-C2 (PN 160001) and Hamilton-C3 (PN 160005) Ventilator Unit
  • Manufacturer

Manufacturer