HeartStart MRx monitor/defibrillator 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Philips Healthcare 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-07-17
  • 사례 출판 날짜
    2012-07-17
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: philips heartstart mrx monitor/defibrillator medical device manufacturer, philips healthcare, has issued a field safety notice concerning heartstart mrx monitor/defibrillator. the affected units included all heartstart mrx monitor/defibrillator manufactured prior to june 2012 and used in external transport and emergency medical service (ems) environments. the affected model numbers included: m3535a, m3536a, m3536j, m3536m, m3536mc, m3536m1, m3536m2, m3536m3, m3536m4, m3536m5, and m3536m6. according to the manufacturer, when used in ems environments, the mechanical/electrical connection (connector pins and/or port pins) between the pads/paddles therapy cable (including pads cpr therapy cable and external paddles cable) and the mrx therapy connection port may experience high levels of stress causing accelerated wear. without routine periodic inspections and preventive action by users, accelerated wear of the connection could ultimately prevent the device from sensing that the pads/paddles therapy cable is connected. this wear also may cause the mrx to misidentify the pads therapy cable, external paddles, or internal paddles when they are connected to the therapy port which could result in a delay of therapy, incorrect energy delivered, spontaneous/unintended therapy energy discharge, shock to caregiver when delivering therapy, and/or interrupted pacing with lost capture and inability to regain cardiac recapture. the manufacturer advised users to read the attached heartstart mrx instructions for use addendum which describes how a user can identify wear, and immediately implement ongoing therapy connection inspection on all of mrx devices to detect wear from higher than expected levels of stress. if wear is detected, remove affected devices immediately from use and contact philips to arrange for service. replace therapy cables/external paddles every three years from the time they were initially placed into service or if they fail the inspection criteria in the attached instructions for use addendum. according to the local supplier, the affected devices were distributed in hong kong. if you are in possession of the products, please contact your supplier for necessary actions. posted on 17 july 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Philips HeartStart MRx monitor/defibrillator