heartstart xl defibrillator/ monitor battery m3516a 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Philips Healthcare 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-10-03
  • 사례 출판 날짜
    2012-10-03
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: philips heartstart xl defibrillator/ monitor battery m3516a the medicines and healthcare products regulatory agency (mhra), united kingdom and the health canada posted a medical device safety alert concerning heartstart xl defibrillator/monitor battery m3516a, manufactured by philips healthcare. the affected products were labeled with “made in taiwan” and has “r-2011-12” as date of manufacture code. according to philips, the affected battery may not trigger a low battery alarm on the heartstart xl defibrillator/monitor (m4735a). in this case, if the heartstart xl is used on a patient when ac power is not in use, with a battery that may fail, the device may shut down unexpectedly without providing the user with a low battery warning message or audible tone. there is a potential for patient harm if the xl shuts down or becomes inoperable when in clinical use for providing therapy. therefore, philips recommends the following actions: operate the xl with ac power instead of battery power alone. if it is needed to operate the xl on battery power alone, ensure the battery is from a different date of manufacture (it must not have the r-2011-12 date of manufacture code). if unable to operate with ac power alone or locate a battery with a different date of manufacture than that identified above, use an alternative source for treatment or therapy (i.E., backup defibrillator/monitor). according to the local supplier, the affected products have been distributed in hong kong. for details, please refer to the mhra and health canada websites as below: http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/con185586 http://www.Hc-sc.Gc.Ca/dhp-mps/compli-conform/recall-retrait/_list/rec-ret_md-im_date_oct-dec_2012-eng.Php if you are in possession of the products, please contact your supplier for information and necessary actions. posted on 3 october 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Philips HeartStart XL Defibrillator/ Monitor Battery M3516A