Hemodialysis Device DBB-06 and DBB-07 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Nikkiso Co. Ltd. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-10-17
  • 사례 출판 날짜
    2012-10-17
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: nikkiso hemodialysis device dbb-06 and dbb-07 the medicines and healthcare products regulatory agency (mhra), united kingdom posted a medical device safety alert concerning hemodialysis device dbb-06 and dbb-07 [ref. no.: ge-f110-00, ge-f111-00, ge-f112-00, ge-f114-00 and ge-f115-00]. the date of manufacturing of the affected products were september 2012 and before nikkiso has received two complaints from a hospital technical department regarding too high a patient leakage current with the dbb-06 devices, used in combination with a central venous catheter (cvc). the current is normally taken to ground via the earth conductor in the mains cable; however if the conductor is compromised the current will pass through the dialysate lines and dialyser to the central venous catheter and then to ground via any earthed surface the patient touches. therefore, if the patient leakage current exceeds the recommendation of 10μa for type cf applied parts with a direct cardiac application there is a risk that the current could become concentrated at the catheter tip and could exceed the level that would induce ventricular fibrillation. models dbb-06 and dbb-07 have a patient leakage current higher than that specified for type cf applied parts. apart from the two complaints mentioned above, no incident or complaint related to a too high patient leakage current was filed for both devices. the manufacturer reminded users to consider that dbb-06 and dbb-07 devices may have additional risks in cvc treatment mode. field service engineers of the manufacturer will modify the hardware of the dbb-06 and dbb-07 devices and check the compliance to the new established patient leakage current within the yearly standard preventive maintenance activities. for details, please refer to the mhra website as below: http://www.Mhra.Gov.Uk/safetyinformation/safetywarningsalertsandrecalls/fieldsafetynotices/con189227 if you are in possession of the affected product, please contact your supplier for necessary actions. . posted on 17 october 2012.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: NIKKISO Hemodialysis Device DBB-06 and DBB-07