Intragastric balloon systems 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Apollo Endosurgery) and ReShape Integrated Dual Balloon System 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2018-07-18
  • 사례 출판 날짜
    2018-07-18
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: intragastric balloon systems the therapeutic goods administration (tga) of australian government has conducted a product safety review of two intragastric balloon systems on the australian register of therapeutic goods, including orbera intragastric balloon system (manufactured by apollo endosurgery) and reshape integrated dual balloon system (manufactured by reshape lifesciences). tga's review follows information published by food and drug administration (fda) of the united states about deaths and serious injuries to patients associated with use of intragastric balloons to treat obesity. tga has received 19 adverse event reports since 2009 regarding the intragastric balloon systems that are currently being supplied in australia. these reports include three patient deaths. tga is working with sponsors and manufacturers to ensure clinicians and patients are fully informed of the risks with this type of device. information for health professionals and patients as below: if doctors are treating a patient who has an intragastric balloon, be alert to symptoms that might indicate there is an issue associated with the device. adverse events associated with these devices include: obstruction; ulceration; necrosis; ischaemia (gastric or intestinal); spontaneous hyperinflation of the balloon; perforation (oesophageal, gastric or intestinal); gastritis/ gastric erosions; acute pancreatitis. where relevant, patients should be advised to take the necessary precautions to prevent pregnancy prior to placement and throughout the duration of treatment, and be instructed to inform doctors as soon as possible if pregnancy is confirmed during treatment, so that removal of the device can be arranged. tga recommends that doctors monitor patients closely during the entire term of treatment with intragastric balloon systems for possible complications. in particular, be aware that patients with an intragastric balloon who present with severe abdominal pain and have a negative endoscopy and x-ray, may still require a ct scan to definitively rule out a perforation. an intragastric balloon should not be used in patients who: are under 18 years of age; have had previous upper gastrointestinal surgery; regularly take aspirin, non-steroidal anti-inflammatory agents, cox-2 inhibitors, anti-coagulants or anti-platelet agents; are pregnant; have a clinically significant hiatus hernia; have a history of inflammatory disease of the gastrointestinal tract. there are other conditions that may also preclude use of an intragastric balloon, and so it is important that patients discuss complete medical history with doctors. if they or someone they provide care for has an intragastric balloon system in place, be alert to potential issues. complications (mentioned in the adverse events), although rare, may require abdominal surgery, or have serious consequences including death. symptoms to watch out for include persistent or recurrent abdominal pain, swelling of the abdomen, vomiting, difficulty breathing or back pain. do not ignore these symptoms and seek medical attention as soon as possible. for detailed information, please refer to tga website https://www.Tga.Gov.Au/alert/intragastric-balloon-systems. posted on 18 july 2018.

Device