Intrauterine Devices 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Eurogine S.L. 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2018-02-28
  • 사례 출판 날짜
    2018-02-28
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: eurogine s.L. intrauterine devices medical device manufacturer, eurogine s.L., has issued a medical device safety alert concerning its intrauterine devices (iud). the affected devices are identified as the following: - model: ancora [lots: 0114, 0614, 1114, 0415]: ref. 01030000 ancora 375 cu normal ref. 01030400 ancora 375 ag normal ref. 01030200 ancora 250 cu mini iud to be replaced as preventive action [lots: 1115, 0616, 1116, 0217, 0417, 0917]: ref. 01010500 novaplus t 380 ag normal ref. 01010600 novaplus t 380 ag mini ref. 01010700 novaplus t 380 ag maxi ref. 01020100 novaplus t 380 cu normal ref. 01020200 novaplus t 380 cu mini ref. 01030000 ancora 375 cu normal ref. 01030400 ancora 375 ag normal ref. 01030200 ancora 250 cu mini ref. 01040000 gold t maxi ref. 01040100 gold t normal ref. 01040200 gold t mini an increase in breaks in the horizontal arms (one or both) was observed at the time of the extraction of the iud model ancora. after the investigation carried out, it can be concluded that the main cause that has generated this situation is a deficient manufacturing of the raw material by the manufacturer/supplier. the mixture between the polymer and barium sulphate was correct in proportion, but agglomerates have appeared in a random way that can embitter the product, in spite that this parameter is controlled and certified by the manufacturer of the raw material. according to the manufacturer, the reported ruptures have mostly occurred at the moment of the extraction of the iud and in the same area of the structure that is the angle of union of the horizontal arms with the vertical axis. this is the part that suffers the greatest mechanical stress in all the iuds in "ω" shape, at the time of insertion but especially in the extraction. the combination between the extraction system (torsion of the arms) and possible agglomerations of barium sulphate in the torsion zone can cause the breakage of the device. based on the current data and the nature of the breakage, the efficacy of the iud is not affected and therefore premature removal of the device is not recommended. for programmed extractions, it is recommended to perform a slow and constant traction when pulling the threads. product replacement is on-going. in the event that a rupture should occur and a fragment remains inside the uterus, monitor by ultrasound and assess at the physician's discretion the possibility of: wait for a sufficient period of time to allow the spontaneous expulsion of the fragment during menstruation. if it does not occur, remove the fragment with a mathieu extractor gripper or similar through the cervical canal in the last case, assess the need to perform a hysteroscopy to remove the fragment according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 28 february 2018.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Eurogine S.L. Intrauterine Devices (Updates)
  • Manufacturer

Manufacturer