Locking Compression Plate Drill Sleeve 1.5 f/Drill Bit ø1.1mm 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Synthes GmbH 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2017-08-15
  • 사례 출판 날짜
    2017-08-15
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: synthes gmbh locking compression plate drill sleeve 1.5 f/drill bit ø1.1mm medical device manufacturer, synthes gmbh, has issued a medical device safety alert concerning its locking compression plate (lcp) drill sleeve 1.5 f/drill bit ø1.1mm. [part number: 03.114.001; lot numbers: 9972971, h028400, h161606, h288454]. the manufacturer is initiating a voluntary field safety notification for the above lots of the lcp drill sleeve which is part of the 1.5 mm lcp modular mini fragment system. the lcp compact hand 1.5 implants are intended for temporary fixation, correction or stabilization of bones in anatomical region of the hand. drill/protection guide/sleeves are intended for holding and guiding implants and instruments during orthopaedic surgery. according to the manufacturer, there may be difficulty attaching the affected lots of the drill sleeve to the plate. if the drill sleeve will not connect to the plate intraoperatively, surgical delay could occur. additionally, if the pilot hole is drilled without the drill sleeve, the pilot hole could be off-center which could result in screw and/or plate loosening. affected users are not required to return the synthes lcp drill sleeves. they are advised to pre-assemble the drill sleeve with the plate preoperatively. if they experience difficulty connecting the drill sleeve to the plate, they should use the additional 1.1 mm locking drill sleeve provided in the graphic case, or: align the 1.1 mm drill bit to the plate as perpendicular as possible and then drill freehand and the locking screw can be engaged in this manner. if the drill hole must be used and no option to lock remains, a non-locking screw can be used. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 15 august 2017.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Synthes GmbH Locking Compression Plate Drill Sleeve 1.5 f/Drill Bit ø1.1mm
  • Manufacturer

Manufacturer