MagNA Pure 24 System 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Roche Diagnostics 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2018-05-02
  • 사례 출판 날짜
    2018-05-02
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: roche diagnostics magna pure 24 system medical device manufacturer, roche diagnostics, has issued a medical device safety alert concerning its magna pure 24 system [gmmi number: 7290519001]. cross-contamination of samples has been reported, by an external collaborator, when running the existing pathogen200 protocol on the magna pure 24 system. the manufacturer’s internal investigation has confirmed the issue for the launched pathogen200 and pathogen1000 protocols. the cross-contamination of samples during pathogen nucleic acid extraction can create false positive or over-quantified results, which may result in exposure to unnecessary medication side effects or medical procedures that have a remote probability of creating adverse health consequences. according to the manufacturer, cross-contamination is caused by a too low offset value for magnetic glass particle (mgp) pre-dispensing to the reagent wells of the processing cartridge. reagent wells on the processing cartridge are used to pre-dispense all reagents. processing tips transfer reagents to the samples in the processing wells of the processing cartridge. the processing tips used for this transfer have already been in contact with the sample material and therefore contaminate the remaining liquid in the reagent wells. in most cases, laboratories do not need to review previous results or retest patients because cross contamination and the generation of false positive results are likely to be quite rare and require the presence of a high titer source sample. a review of previous results would only be relevant in cases where the magna pure 24 pathogen protocols (200 and/or 1000) were used to extract nucleic acids for an assay for a chronic infectious disease (e.G., hepatitis c) and a change in result reporting could impact patient management. suspected false positives that could potentially affect patient management should be retested according to local procedures, using either the magna pure 24 instrument with the newly launched pathogen200 hp or fast pathogen 200 protocols or external lysis pathogen 200 and 500 protocols or an alternative method. the affected users are advised to take the following actions until the updated pathogen200 and pathogen1000 protocols are available: utilize the newly launched pathogen200 hp or fast pathogen 200 protocols or external lysis pathogen 200 and 500 protocols; utilize an alternative method for testing purposes according to the local supplier, the affected product is distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 2 may 2018.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Roche Diagnostics MagNA Pure 24 System
  • Manufacturer

Manufacturer