Magnetic Silica (MagSIL) used in NucliSENS easyMAG nucleic acid extraction system 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Biomérieux 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2016-07-18
  • 사례 출판 날짜
    2016-07-18
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: biomérieux magnetic silica (magsil) used in nuclisens easymag nucleic acid extraction system medical device manufacturer, biomérieux, has issued a medical device safety alert concerning its magnetic silica (magsil) (reference number: 280133) used in nuclisens easymag nucleic acid extraction system. the lot numbers affected by this issue are described below. lot numbers (expiration date): z0i7bb1ms (28/02/2017), z017bf1ms (28/02/2017), z017ca1ms (28/03/2017), z017be1ms (28/02/2017), z017cc1ms (28/03/2017), z017cd1ms (28/03/2017), z017ch1ms (28/03/2017), z017bd1ms (28/02/2017), z017db1ms (28/04/2017), z017ba1ms (28/02/2017), z017cf1ms (28/03/2017), z017ce1ms (28/03/2017), z017cg1ms (28/03/2017), z017da1ms (28/04/2017) , z017dc1ms (28/04/2017), z017dd1ms (28/04/2017), z017ea1ms (28/05/2017), z017eb1ms (28/05/2017), z017fb1ms (28/06/2017), z017fa1ms (28/06/2017), z017kc1ms (28/09/2017), z017kf1ms (28/09/2017), z017kg1ms (28/09/2017), z017kh1ms (28/09/2017), z017la1ms (28/10/2017) ]. following customer complaints about amplification performance issues with home brew pcr and rt-pcr assays, the manufacturer’s investigation has observed a decrease of extraction performances for some specific downstream applications due to the specific batches of magnetic silica (magsil). the investigation demonstrated no or not significant impact on performances when using nuclisens easymag extraction reagents with the biomerieux ivd downstream applications (pcr/rt-pcr argene) and nuclisens easyq hiv1 v2.0 (nasba technology). the investigation concluded that downstream applications were only impacted when the extraction volume was higher than 400µl and for double stranded nucleic acids target. double stranded nucleic acid applications with small (<40kbp) and medium genome sizes (<to 1200 kbp) i.E dna viruses are more impacted than higher human genomic dna and bacterial applications (>to l200kbp). single stranded rna virus applications are not impacted unless the rna is extracted without a matrix (i.E. in water). according to the manufacturer, the decrease of downstream application performances can lead to a risk of false negative, invalid or under-quantification results. however, this risk can be managed by following good laboratory practice with the use of appropriate controls (ic with same nature/structure than the target and/or external controls) that should detect the issue, especially false negative or under-quantification results. product recall and replacement is on-going. the customers are advised to take the following actions: reduce the sample input volume to 200µl until the silica problem is solved. use an extraction internal control which mimic the target (with same nature/structure), and/or external controls as recommended in the ifu and in good laboratory practice to detect any extraction performance issue. discuss any concern regarding previously reported results with the laboratory medical director to determine the appropriate course of action. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 18 july 2016.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 의료기기 분류등급
  • 제품 설명
    Medical Device Safety Alert: Biomérieux Magnetic Silica (MagSIL) used in NucliSENS easyMAG nucleic acid extraction system