maquet servo-i/s ventilator systems with software version 8.00.00 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 MAQUET 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2016-06-17
  • 사례 출판 날짜
    2016-06-17
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Medical device safety alert: maquet servo-i/s ventilator systems with software version 8.00.00 the australia therapeutic goods administration (tga) has issued a medical device safety alert concerning servo-i/s ventilator systems with software version 8.00.00 [part numbers: 68 85 247, 68 85 259]. the manufacturer has become aware of improper behaviour introduced in servo-i and servo-s ventilator system sw version 8.00.00, which appears as follows:- if ventilation is started with infant factory default settings, the following settings will apply: pressure control mode; and 10 cmh2o pc above peep. the system will deliver a pressure of 20 cmh2o above peep as long as the factory default setting 10 cmh2o is used unchanged. according to the manufacturer, there is a risk of serious injury to an infant. however, the issue would be apparent in the pressure curve and peak pressure displayed on the screen. there are no reported injuries. users are advised to change the default settings of pressure above peep in the infant patient category. the ventilator will only deliver a pressure of 20 cmh2o above peep if the default start-up configuration of the pressure has not been changed. the manufacturer will be upgrading all affected units as a permanent correction. according to the local supplier, the affected products are not distributed in hong kong. if you are in possession of the affected products, please contact your supplier for necessary actions. posted on 17 june 2016.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: Maquet SERVO-i/s ventilator systems with software version 8.00.00