MITCH TRH acetabular cups/MITCH TRH modular heads (Finsbury Orthopaedics) implanted with uncemented Accolade femoral stems (Stryker Orthopaedics) 의 안전성 경고

Department of Health에 따르면, 해당 안전성 경고 는 Hong Kong 에서 Finsbury Orthopaedics 에 의해 제조된 제품과 관련되어 있습니다.

이것은 무엇인가요?

안전성 경고는 의료기기 제품과 관련된 중요한 정보와 권고사항을 담고 있습니다. 물론 안전성 경고가 배포되었다고 해서 해당 제품이 무조건 안전하지 않은 제품이라는 것은 아닙니다. 보건의료업계 종사자와 의료기기 사용자들에게 배포되는 안전성 경고에는 회수(recall)도 포함될 수 있습니다. 제조사가 안전성 경고를 작성하기도 하지만, 보건당국에서 작성하는 경우도 있습니다.

데이터에 대해 더 자세히 알아보기 여기
  • 사례 유형
    Safety alert
  • 날짜
    2012-04-03
  • 사례 국가
  • 사례 출처
    DH
  • 사례 출처 URL
  • 비고 / 경고
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • 데이터 추가 비고
    Medical Device Safety Alert
  • 원인
    Mhra issued new advice about metal-on-metal total hip replacements: mitch trh acetabular cups/mitch trh modular heads (finsbury orthopaedics) implanted with uncemented accolade femoral stems (stryker orthopaedics) the united kingdom (uk) medicines and healthcare products regulatory agency (mhra) issued advice to orthopaedic surgeons to stop implanting mitch trh acetabular cups/mitch trh modular heads in combination with uncemented accolade femoral stems. it is because this particular combination has a high revision rate (10.7%) compared to other types of hip implant. the mhra also provided follow-up recommendations to patients with this combination of implant. the mitch trh system is a metal-on-metal hip replacement system consisting of components that can be used in different combinations to carry out either hip resurfacing arthroplasty or total hip replacement. the system was manufactured by finsbury orthopaedics and was distributed in the uk by stryker orthopaedics between may 2006 and october 2011. analysis of data from the england and wales national joint registry (njr) up to 10 march 2012 has shown that the cumulative revision rate for mitch trh system total hip replacements (revision rate of 8.8% at 4 years based on 445 patients recorded by the njr) is higher than indicated as acceptable by the national institute for health and clinical excellence. further analysis of njr data has now determined that the cumulative revision rate of mitch trh system total hip replacements varies considerably depending upon which femoral stem is used: mitch trh with exeter v40 – revision rate of 3.7% at 4 years based on 120 patients recorded by the njr mitch trh with uncemented accolade – revision rate of 10.7% at 4 years based on 271 patients recorded by the njr mitch trh with abg ii - rate of usage too low to estimate revision rate in view of the high revision rate when mitch trh acetabular cups/mitch trh modular heads is used in combination with uncemented accolade femoral stems, mhra advised orthopaedic surgeons to stop using this combination and provided advice on appropriate follow-up recommendations for patients with this combination of implant. according to the local supplier, this particular combination has not been distributed in hong kong. for details regarding the mhra’s latest management recommendations, please visit: http://www.Mhra.Gov.Uk/publications/safetywarnings/ medicaldevicealerts/con149600 http://www.Mhra.Gov.Uk/newscentre/pressreleases/con149601.

Device

  • 모델명 / 제조번호(시리얼번호)
  • 제품 설명
    Medical Device Safety Alert: MITCH TRH acetabular cups/MITCH TRH modular heads (Finsbury Orthopaedics) implanted with uncemented Accolade femoral stems (Stryker Orthopaedics)